Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Sitemtc-m21c.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador8JMKD3MGP3W34R/3SA3N2E
Repositóriosid.inpe.br/mtc-m21c/2018/11.27.10.41   (acesso restrito)
Última Atualização2018:11.27.10.41.49 (UTC) simone
Repositório de Metadadossid.inpe.br/mtc-m21c/2018/11.27.10.41.49
Última Atualização dos Metadados2019:01.14.17.06.39 (UTC) administrator
DOI10.1016/j.surfcoat.2018.05.009
ISSN0257-8972
Chave de CitaçãoUedaSilMarReuSou:2018:ReExPl
TítuloRecent experiments on plasma immersion ion implantation (and deposition) using discharges inside metal tubes
Ano2018
MêsDec.
Data de Acesso08 maio 2024
Tipo de Trabalhojournal article
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho4275 KiB
2. Contextualização
Autor1 Ueda, Mário
2 Silva, C.
3 Marcondes, André Ricardo
4 Reuther, H.
5 Souza, G. B. de
Identificador de Curriculo1 8JMKD3MGP5W/3C9JHSB
2
3 8JMKD3MGP5W/3C9JGHM
Grupo1 LABAP-COCTE-INPE-MCTIC-GOV-BR
2 LABAP-COCTE-INPE-MCTIC-GOV-BR
3 LABAP-COCTE-INPE-MCTIC-GOV-BR
Afiliação1 Instituto Nacional de Pesquisas Espaciais (INPE)
2 Instituto Nacional de Pesquisas Espaciais (INPE)
3 Instituto Nacional de Pesquisas Espaciais (INPE)
4 HZDR, Rossendorf
5 Universidade Estadual de Ponta Grossa (UEPG)
Endereço de e-Mail do Autor1 mario.ueda@inpe.br
2
3 andre.marcondes@inpe.br
RevistaSurface and Coatings Technology
Volume355
NúmeroSpecial
Páginas98-110
Nota SecundáriaA1_MATERIAIS A1_ENGENHARIAS_II A2_SAÚDE_COLETIVA A2_INTERDISCIPLINAR A2_GEOCIÊNCIAS A2_ENGENHARIAS_III B1_ODONTOLOGIA B1_MEDICINA_II B1_ENGENHARIAS_IV B1_ASTRONOMIA_/_FÍSICA B2_QUÍMICA B2_CIÊNCIAS_BIOLÓGICAS_I
Histórico (UTC)2018-11-27 10:41:49 :: simone -> administrator ::
2018-11-27 10:41:50 :: administrator -> simone :: 2018
2018-11-27 10:42:50 :: simone -> administrator :: 2018
2019-01-14 17:06:39 :: administrator -> simone :: 2018
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-ChavePlasma immersion ion implantation
Sputtering and deposition inside metallic tubes
Tubes with different dimensions and configurations
TiN and Ti2N in high temperature PIII
ResumoPlasma immersion ion implantation (PIII) of nitrogen inside metallic tubes of different diameters and configurations were attempted recently. PIII tests in practical size metallic tubes of SS304, ranging from 1.1 to 16 cm empty set and length of 20 cm, were carried out as a continued effort in our lab, to explore PIII inside tubes. Tubes in laying down positions and configurations including metallic lid in one side or both sides open were used, as well as, plane sample support placed 10 cm far from the tube mouth and without bias, taking advantage of plasma flowing out the tube. In particular, nitrogen and argon PIIIs were tested for tube inner wall sputtering and deposition studies, running the PIII system in the last configuration of sample support detached from the tube. During the nitrogen ion implantation runs in other cases, it was found that the final temperature of the tubes and the plasma turn-on voltages were both inversely proportional to the dimensions of the tubes, except for the smallest tube tested. High voltage glow and hollow cathode discharges were produced inside the tubes, either alternately, during the pulse or independently, depending on the tube geometry and pulser used (LIITS, a current controlled source or RUP-4, a voltage controlled one). In the case of smallest diameter of 1.1 cm empty set, a suspended tube of SS304 was tested using lower power pulser (RUP-4), at its near maximum capability of 1.2 kW. In this case also, very bright plasmas were formed, mainly inside the tube and resulted in high temperature there (similar to 700 degrees C). Nitrogen uptake was superior for higher temperature PIII treatments (> 700 degrees C), combining ion implantation and thermal diffusion, which allowed the formation of TiN and Ti2N on the Ti alloy samples inside tubes with diameters <= 4 cm. In this paper, detailed discussion of results of above cited PIII tests with diversified tubes and configurations are presented, together with the analysis of the corresponding treated surfaces of the samples inside, outside and on the support detached from the tube.
ÁreaFISPLASMA
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > LABAP > Recent experiments on...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreement
agreement.html 27/11/2018 08:41 1.0 KiB 
4. Condições de acesso e uso
Idiomaen
Arquivo Alvoueda_recent.pdf
Grupo de Usuáriossimone
Grupo de Leitoresadministrator
simone
Visibilidadeshown
Política de Arquivamentodenypublisher denyfinaldraft24
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/3ET2RFS
Lista de Itens Citandosid.inpe.br/bibdigital/2013/09.25.21.49 1
sid.inpe.br/mtc-m21/2012/07.13.14.56.06 1
DivulgaçãoWEBSCI; PORTALCAPES; COMPENDEX.
Acervo Hospedeirourlib.net/www/2017/11.22.19.04
6. Notas
Campos Vaziosalternatejournal archivist callnumber copyholder copyright creatorhistory descriptionlevel e-mailaddress format isbn label lineage mark mirrorrepository nextedition notes orcid parameterlist parentrepositories previousedition previouslowerunit progress project rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject tertiarymark tertiarytype url
7. Controle da descrição
e-Mail (login)simone
atualizar 


Fechar